Basement Flood Defense Sizing

Sump Pump Inrush & LRA Surge Checker

Sump pumps and inductive induction motors draw an enormous spike in instantaneous current when the rotor starts from a dead standstill. Calculate whether your portable inverter can absorb this surge without tripping.

Inductive Inrush Multiplier:3.5x
Soft-start (2.5x)Standard (3.5x)Locked Rotor LRA (5x)
Required Inrush Starting Surge
2,100 W
Locked Rotor Current: ~17.5 Amps @ 120V
Min. Continuous Inverter:1200W
Min. Peak Surge Headroom:2415W Peak
Running Amperage:5.0A (Steady state)

Understanding Locked Rotor Amperage (LRA)

When an AC electric motor is stationary, there is zero back-electromotive force (back-EMF) to resist the incoming electrical current. For the first 100 to 300 milliseconds, the motor behaves almost like a dead short across the AC terminals. This initial draw is known as Locked Rotor Amps (LRA).

🌊 1/2 Horsepower Motor Reality

A standard 1/2 HP submersible sump pump draws around 800W to 1,050W while running continuously. However, its startup spike frequently peaks between 2,800W and 3,800W for a fraction of a second. A 2,000W rated inverter will immediately shut down into overload fault protection.

⚡ Inverter Peak Surge Durations

Most solar generators specify a peak surge limit (e.g. 4,800W for a 2,400W inverter), but this peak rating is often only rated for 20ms to 500ms before electronic circuit breakers activate to protect the internal MOSFETs.